Determination of 11 fluorescent whitening agents in fresh tea drinks by ultra-high performance liquid chromatography-tandem mass spectrometry
Author:
Affiliation:

Center for Disease Control and Prevention of Yancheng, Yancheng Center of Jiangsu Food Safety Risk Monitoring,Yancheng Center of Molecular Biology in Public Health, Jiangsu Yancheng 224000, China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 建立超高效液相色谱-串联质谱法测定现制茶饮中11种荧光增白剂的方法。方法 样品经N,N-二甲基甲酰胺/水/三乙胺(70∶29∶1,V/V/V)超声提取,加适量沉淀剂,离心过滤后,进UPLC-MS/MS系统,以乙腈-0.2%氨水为流动相,梯度洗脱,经Waters BEH C18(2.1 mm×100 mm,1.7 μm)色谱柱分离,采用ESI源,正负离子同时扫描的多反应监测模式进行检测,外标法定量。结果 11种荧光增白剂在各自的线性范围内线性良好,相关系数(r)均>0.995,方法检出限为0.003~0.03 mg/kg,方法定量限0.01~0.1 mg/kg,在奶茶、果茶和咖啡3类现制茶饮中进行低、中、高3水平加标,回收率范围为71.7%~116.9%,相对标准偏差(RSDs)范围为0.7%~9.9%。结论 该方法简单、高效、准确,适用于奶茶、果茶和咖啡等现制茶饮中11种荧光增白剂的检测,为现制茶饮相关的食品安全监管提供方法。

    Abstract:

    Objective To establish an analytical method for determination of 11 fluorescent whitening agents in fresh tea drinks using ultra-high performance liquid chromatography-tandem mass spectrometry.Methods The samples were extracted by sonication of N, N-dimethylformamide/water/triethylamine (70∶29∶1, V/V/V) , added with appropriate precipitant, centrifuged and filtered, finally injected into the UPLC-MS/MS system. The samples were separated on a Waters BEH C18 column (2.1 mm×50 mm,1.7 μm) with acetonitrile and 0.2% ammonia as mobile phase,and detected using electrospray ionization in multiple reaction monitoring mode via positive and negative ions scanning. Compounds were quantified by external standard method.Results The 11 fluorescent whitening agents had good linearity within the measured concentration range, and the correlation coefficients (r) were all above 0.995. The limits of detection were 0.003-0.03 mg/kg. The limits of quantitation were 0.01-0.1 mg/kg. The recoveries were 71.7%-116.% and the relative standard deviations were 0.7%-9.9% in three kinds of fresh tea drinks including milk tea, fruit tea and coffee.Conclusion The proposed method is simple, highly efficient, accurate, and suitable for the detection of 11 kinds of fluorescent whitening agents in fresh tea drinks such as milk tea, fruit tea and coffee, which provides a methods for food safety supervision related to fresh tea production.