胶体金免疫层析技术快速检测谷物中3种真菌毒素的研究
作者:
作者单位:

(1.武警后勤部疾病预防控制中心,北京 102613;2.郑州中道生物技术有限公司,河南 郑州 450000)

作者简介:

曹德康 男 主任医师 研究方向为军事预防医学及环境监测 E-mail:13301080538@163.com通信作者:┣┣(中)通信作者┫┫苏建忠 男 主治医师 研究方向为卫生监督及环境监测 E-mail:wjsjz@139.com

通讯作者:

中图分类号:

基金项目:

武警后勤部卫生局科研课题(WJWSB2015-01)


Research on the rapid detection of three kinds of mycotoxin in grains by colloidal gold immunochromatographic method
Author:
Affiliation:

(1.Center for Diseases Control and Prevention of Chinese People's Armed Police Forces, Beijing 102613,China;2.Zhengzhou Zhongdao Biotechnology Co., Ltd,Henan Zhengzhou 450000,China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    应用胶体金免疫层析技术开发一种快速检测谷物中黄曲霉毒素B1(AFB1)、玉米赤霉烯酮(ZEN)和呕吐毒素(DON)的三联检测卡。方法 优化胶体金溶液pH值、金标抗体量及抗原包被量制备3种胶体金试纸条,将试纸条组装成检测卡,研究该卡的检测限、准确度、特异性和稳定性。结果 AFB1、ZEN和DON 3种试纸条的胶体金溶液最适pH值分别为7.5、7.5和7.0,金标抗体量分别为4.2、7.2和9.6 μg/ml,抗原包被量分别为1.0、1.4和0.8 mg/ml。检测卡的检测结果与仪器检测结果基本一致,重复性较好,与结构类似物及其他霉菌毒素无交叉反应,在室温条件下可以保存12个月。结论 该三联检测卡操作简便、快速、准确、稳定,且能同时检测3种真菌毒素,在谷物的现场检测中有较好的应用前景。

    Abstract:

    The colloidal gold immunochromatographic strip was developed to detect aflatoxin B1 (AFB1), zearalenone (ZEN) and deoxynivalenol (DON) in grains. Methods The pH of colloidal gold solution and the dosage of the specific antibody and antigen were optimized through three combinations. The limit of quantitation, accuracy, specificity and the stability of the detection strip were investigated. Results The optimal pH of colloidal gold solution for AFB1, ZEN and DON was 7.5,7.5 and 7.0, respectively. The optimal concentration of antibody marking was 4.2,7.2 and 9.6 μg/ml, respectively. The optimal concentration of the specific antigen was 1.0,1.4 and 0.8 mg/ml, respectively. Sixty samples were detected through instrument method and colloidal gold immunochromatographic method simultaneously, and the results were consistent with each other. No cross-reaction was observed with other analogue and mycotoxins, and the triple strip could be stored at room temperature for 12 months. Conclusion The triple strip was a simple, accurate and stable method for monitoring AFB1, ZEN and DON in grains, and had good application foreground in field analysis.