The identification of Cronobacter sakazakii and its traceability by matrix-assisted laser desorption ionization-time of flight mass spectrometry
CSTR:
Author:
Affiliation:

(1.School of Biological Engineering, Dalian Polytechnic University, Liaoning Dalian 116034, China;2.Chinese Academy of Inspection and Quarantine, Beijing 100176,China;3.National Dairy Engineering and Technical Research Center, Heilongjiang Harbin 150086, China)

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Objective VITEK matrix-assisted laster desorption ionization-time of flight mass spectrometry (VITEK MALDI-TOF MS,hereinafter referred to as VITEK MS). To study the impact of different sample preparation procedures for Cronobacter sakazakii identification and its traceability. And two data acquisition softwares of VITEK MS and MALDI 7090 were used to compare the differences of mass spectrograms between them. Methods Twenty two strains, including 18 isolated Cronobacter sakazakii strains, two Cronobacter sakazakii reference strains, one Enterobacter cloacae reference strain and one Citrobacter freundii reference strain were prepared respectively by three different preparation procedures, including direct transfer method, formic acid extraction method and formic acid-acetonitrile extraction method, and analyzed by MS. A detailed analysis of mass spectrograms was obtained from the software of VITEK MS. The result were compared with biochemical result. Then, the impact of sample preparation method on the identification result was evaluated by researching the consistency of result derived from three different preparation method, The traceability of 20 Cronobacter sakazakii strains was also investigated by the cluster analysis of VITEK MS result. The same strains were analyzed by MALDI 7090, and the mass spectrograms were compared with those by VITEK MS. Results The 20 strains were identified by VITEK MS as Cronobacter sakazakii, which were in consistent with biochemical result and could be distinguished from Enterobacter cloacae and Citrobacter freundii. There was no significant difference in the result confidence among the three different preparation procedures(P>0.05), but the number of mass peaks and their relative intensities showed remarkable difference. The formic acid extraction method achieved spectra consisting of >15 peaks and mass ranges of 2 000-15 000 m/z, of which relative intensities were >5 mV. At similarity level of 80%, the 20 strains prepared by the formic acid extraction method were classified into 5 clusters by the cluster analysis of VITEK MS result, through which the transmission route of Cronobacter sakazakii could be identified. There was no obvious difference in the peak positions and relative intensity between VITEK MS and MALDI 7090. Conclusion MALDI-TOF MS was considered as a reliable technique in the identification of Cronobacter sakazakii. The formic acid extraction method was more suitable for the identification of Cronobacter sakazakii by MALDI-TOF MS, which will be a useful technique for Cronobacter sakazakii trace. There was no obvious difference in the mass spectrograms between VITEK MS and MALDI 7090.

    Reference
    Related
    Cited by
Get Citation

WANG Wei, ZHAO Hong-yang, LU Yan, WANG Ming-yu, SUN Ying-jian, SONG Jiao-jiao, ZHANG Shun-he, LU Xing-an. The identification of Cronobacter sakazakii and its traceability by matrix-assisted laser desorption ionization-time of flight mass spectrometry[J].中国食品卫生杂志,2018,30(2):125-131.

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:March 01,2018
  • Revised:
  • Adopted:
  • Online: April 28,2018
  • Published:
Article QR Code