Determination of aflatoxin M1 in milk by ultra high performanceliquid chromatography-tandem mass spectrometry
CSTR:
Author:
Affiliation:

(Hebei Province Key Laboratory on Chronic Diseases, Tangshan Key Laboratory for Preclinical and Basic Research on Chronic Diseases, College of Basic Medicine, North China University of Science and Technology,Hebei Tangshan 063000,China)

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    An ultra-high performance liquid chromatography-tandem mass spectrometry method was developed and validated for the analysis of aflatoxin M1in milk.Methods Samples were extracted and cleaned by SPE cartridge. Extracts were analyzed for aflatoxin M1by LC-MS/MS in a single injection with positive electrospray ionization (ESI) mode for aflatoxin M1. Results Recoveries were 94.8%-98.2% in the range of 0.1-10.0 ng/ml with RSDs less than 3.87%. The limit of quantification was 0.005 μg/kg.Conclusion This essay provides an effective way to detect aflatoxin M1 in milk.