Determination of lubricant migration from food contact materials to the lipid food simulant by chromatography-mass spectrometry
CSTR:
Author:
Affiliation:

(Daxing Center for Disease Control and Prevention,Beijing 102600,China)

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    To establish a gas chromatography-mass spectrometry determination method for lubricant migration from food contact materials.Methods Using iooctane, 95% ethanol and MPPO as three kinds of lipids alternatives for food contact materials, the gas chromatography-mass spectrometry detection was conducted after trifluoroacetic anhydride derivation. Results The oleic acid amide and stearic acid amidea had good linear relationship within 0.2-20 mg/L, erucic acid amide and behenamide had good linear relationship within 1.0-30 mg/L. The limits of detection ranged from 0.026 to 0.14 mg/L. The recoveries were in the range of 76.2%-97.3% with the relative standard deviation of 1.2%-6.3%.Conclusion The method was simple, rapid and accurate, and suitable for the detection of lubricants migration from food contact materials in lipid food stimulants.

    Reference
    Related
    Cited by
Get Citation

FANG Ning, WANG Zi-jian, ZHAO Jin-song, WANG Hai-yun, GUO Xiao-yu. Determination of lubricant migration from food contact materials to the lipid food simulant by chromatography-mass spectrometry[J].中国食品卫生杂志,2016,28(3):319-322.