    A method for determination of choline in infant formula by HPLC-ELSD was optimized.Methods The separation was operated on an analtical Agilent ZORBAX 300 SCX column(4.6 mm×250 mm,5 μm)with water (containing 30 mmol/L triethylamine):acetonitrile (80∶20, V/V) as mobile phase.Results The limit of detection was 4 μg/ml. The calibration curve was linear (r=0.998 1). The relative recoveries were 94.98%-100.9%, and relative standard deviations of intra-day and inter-day precision were 2.75% and 3.12%, respectively.Conclusion The method was simple and fast. Compared to the traditional method, analysis time was shorter, and the peak shape of choline is more narrow and symmetrical.

    Reference
    Related
    Cited by
Get Citation

LIU Xue-mei, LIU Bo, GUO Yuan, SHEN Yao, CHEN Bo. Determination of choline in infant formula by high performance liquid chromatography-evaporative light scattering detector[J].中国食品卫生杂志,2016,28(2):219-223.