Determination of dietary iodine in meat by inductively coupled plasma-mass spectrometry
DOI:
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The method for the determination of dietary iodine in meat was developed by inductively coupled plasma-mass spectrometry (ICP-MS).MethodsThe samples were extracted by tetramethylammonium hydroxide and hydrogen peroxide in ultrasonic bathing at 60℃ for 3h and analyzed by ICP-MS after removing fat and protein. 128Te was used to eliminate the matrix interference. ResultsUnder the optimal conditions, this method showed excellent linearity in the range from 1to 200μg/L with a correlation coefficient of 0.9998. The limit of detection was 2.3μg/kg. The relative standard deviations were no more than 5.7% (n=7). The average recoveries of iodine were in the range from 80.0% to 96.6%.ConclusionThis method was efficient and practicable for determining dietary iodine in meat.

    Reference
    Related
    Cited by
Get Citation

ZHANG Ni-na, LIU Li-ping, WU Ke-xin, WANG Zheng. Determination of dietary iodine in meat by inductively coupled plasma-mass spectrometry[J].中国食品卫生杂志,2014,26(2):153-155.

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:August 13,2013
  • Revised:
  • Adopted:
  • Online: April 16,2014
  • Published:
Article QR Code