Determination of hexavalent chromium in foods by GFAAS
DOI:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    A method was developed for the determination of hexavalent chromium in foods.MethodsSamples were microwave extracted with 10% hydrochloric acid for 15min at 120℃.Then extracts were separated with Waters MAX cartridge (500mg, 6cc) and eluted by 5% ammonia water. The hexavalent chromium was indirectly quantified by AAS. ResultsThe lineary range was satisfying within 1-10μg/L, and the correlation coefficients were above 0.999. The limit of detection was 0.0087mg/kg. The recoveries were 90.24%-108.06% with relative standard deviations of 3.19%-6.01%.ConclusionThe method was simple, fast, sensitive, accurate and suitable for the determination of hexavalent chromium in vegetables, fruits, grain and health foods.

    Reference
    Related
    Cited by
Get Citation

CHEN Dong, SHA Bo-yu, ZHAO Rong, WU Guo-hua. Determination of hexavalent chromium in foods by GFAAS[J].中国食品卫生杂志,2014,26(2):150-152.

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:December 27,2013
  • Revised:
  • Adopted:
  • Online: April 16,2014
  • Published: