Development of HPLC determination and LC-IT-TOF verification of DBS in gutter oil
DOI:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    To develop a determination and verification method for DBS in gutter oil and its application. Methods After extracted by 50% ethanol and purified by SPE column, the DBS in gutter oil was detected by HPLC, separated by a Nucleodur C18 column(250mm×4.6mm×5μm) with mobile phase consisting of methanol (containing 20% 10mmol/L ammonium acetate). Verification was operated by LC-IT-TOF mass spectroscopy in ESI-ionization model, nebulizing gas was 1.5ml/min and detector voltage was 1.68kV. ResultsQuantity of DBS in gutter oil was accuratly determined in the range of 4.030-503.3μg/ml, the recoveries were 77%-87% and RSD% of precision was less than 2%. All 7batches of gutter oils and 23batches of edible oils matched the results of verification. Conclusion The method was suitable for the detection of DBS in gutter oil.

    Reference
    Related
    Cited by
Get Citation

Yin Guo, Lu Yi, Xie Pu, Li Yuan, Wang Tiejie. Development of HPLC determination and LC-IT-TOF verification of DBS in gutter oil[J].中国食品卫生杂志,2013,25(1):37-39.